Integrating Spheres for Reflection, Transmission and Absorption

Integrating spheres and accessories optimized for the measurement of reflection, transmission, absorption and photoluminescence.

Integrating spheres optimized for the measurement of reflection, transmission, absorption and photoluminescence.

Model Image Sphere Diameter Spectral range / nm Measurement ports Detector port Geometry Remark
UPB-150-ART UPB-150-ART

150 mm

(300 - 2500) nm 5 knife-edged, 30 mm Ø 30 mm Ø Interchangeable adapters 8°/d, 0°/d, single & dual beam Knife-edged ports for large acceptance angle of scattered radiation. Slide & Fix mounting system
UPB-150-ARTA UPB-150-ARTA

150 mm

(300 - 2500) nm 5 knife-edged, 30 mm Ø 30 mm Ø Interchangeable adapters 8°/d, 0°/d, single & dual beam Universal transmission, reflection, absorption and photo-luminescence. Sample holder for plates and cuvettes in the center of the sphere.
UPG-150-ART UPG-150-ART

150 mm

850 nm - 20 µm 5 knife-edged, 30 mm Ø 30 mm Ø Interchangeable adapters 8°/d, 0°/d, single & dual beam Diffused gold coating with high reflectance and good scattering effect.
SphereSpectro 150H SphereSpectro 150H

150 mm

(240 - 2150) nm 25 mm BTS2048 Spectroradiometers 8°/d Measurement of spectral absorption coefficient and effective scattering coefficient of scattering media, patented technology. Measurement as well of clear samples.
ISMS-30-VAS ISMS-30-VAS

300 mm

VIS 150 mm light source (port reducer available) 75 mm measurement port (different sizes available) 8°/8° Dual use system for reflection measurements on flat, convex and concave displays and annulus design for separating specular, haze and lambertian reflection

Please see also our Spectrophotometers, Laboratory and Analysis Systems with integrating sphere based solutions.

Accessory range including sample holders, cuvette holders, port reducers, light traps and port plugs.

Construction Kit

Model Description Remark
CLS-21 Collimated light source for use with integrating spheres Two beam options: Collimated beam (diameter 1 mm to 10 mm, angle 3,2° full angle), focused beam for distance 150 mm sphere diameter (spot size <7mm)
UPB-150-ART-Z01 Port plug. Flat surface with ODP97 coating. For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z02 Port reducer. Port diameter as specified in 0.1mm steps. Flat surface with ODP97 coating. For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z02-3 Port reducer. 3mm port. Flat surface with ODP97 coating. For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z02-10 Port reducer. 10mm port. Flat surface with ODP97 coating. For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z02-15 Port reducer. 15mm port. Flat surface with ODP97 coating. For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z02-25 Port reducer. 25mm port. Flat surface with ODP97 coating. For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z03 Sample holder For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z04 Light trap For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z05 UMPF-0.5 detector adapter with baffle. For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z06 UMPF-1.0 detector adapter with baffle. For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z07 UMPF-2.0 detector adapter with baffle. For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z09 Port plug with spherical surface For UPB-150-ART and UPB-150-ARTA
UPB-150-ART-Z10 Port reducer. Port diameter as specified in 0.1mm steps. Spherical surface with ODP97 coating. For UPB-150-ART and UPB-150-ARTA
UPB-150-ARTA-Z01 UMPF-0.5 detector adapter with baffle aligned to the sphere center For UPB-150-ARTA
UPB-150-ARTA-Z03 Revolving base plate for the sample holder For UPB-150-ARTA
UPB-150-ARTA-Z04 Cuvette holder For UPB-150-ARTA
UPB-150-ARTA-Z05 Clamp holder For UPB-150-ARTA
UPB-150-ARTA-Z06 Port plug for the upper port, spherical shape For UPB-150-ARTA
UPG-150-ART-Z01 Port plug. Flat surface with Au coating. For UPG-150-ART Gold sphere
UPG-150-ART-Z02 Port reducer. Port diameter as specified in 0.1mm steps. Flat surface with Au coating. For UPG-150-ART Gold sphere
UPG-150-ART-Z02-3 Port reducer. 3mm port. Flat surface with Au coating. For UPG-150-ART Gold sphere
UPG-150-ART-Z02-15 Port reducer. 15mm port. Flat surface with Au coating. For UPG-150-ART Gold sphere
UPG-150-ART-Z02-25 Port reducer. 25mm port. Flat surface with Au coating. For UPG-150-ART Gold sphere
UPG-150-ART-Z03 Sample holder For UPG-150-ART Gold sphere
UPG-150-ART-Z04 Light trap For UPG-150-ART Gold sphere
UPG-150-ART-Z05 UMPF-0.5 detector adapter with baffle. For UPG-150-ART Gold sphere
UPG-150-ART-Z06 UMPF-1.0 detector adapter with baffle. For UPG-150-ART Gold sphere
UPG-150-ART-Z07 UMPF-2.0 detector adapter with baffle. For UPG-150-ART Gold sphere